Send Message
products
PRODUCTS DETAILS
Home > Products >
OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System

MOQ: 1 set
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-200
Type:
Single Stage Centrifugal Pump
Operating Voltage:
18-32VDC
Performance:
Q=2400L/H @ H=17M
Waterproofing Grade:
IP68
Noise:
≤61dB
Weight:
2200g
Product Description

OWP-BL43-200 FIXED WATER PUMP 24VDC 250W HIGH HEAD 16M FOR GLYCOL CIRCULATION.

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 0

Features

 

Centrifugal Pump: Utilizes centrifugal force to move fluid, providing consistent and reliable performance.

 

Magnetic Force Transmission: Ensures smooth operation with minimal mechanical wear by using magnetic coupling.

 

High Efficiency Brushless DC Motor:

Low power consumption.

High efficiency.

Long service life.

 

Wide Range Operating Temperature: Capable of functioning effectively across a broad spectrum of temperatures.

 

Constant Flow Controlling: Maintains a steady flow rate, ensuring consistent performance.

 

Reverse Polarity Protection: Prevents damage from incorrect wiring connections.

 

Dry Running Protection: Automatically shuts down if the pump runs without sufficient liquid, protecting the motor from overheating.

 

Over Voltage Protection: Safeguards against electrical surges.

 

Over Current Protection: Protects the pump from excessive current draw.

 

Overload and Over Temperature Protection: Ensures the pump does not exceed safe operational limits, extending its lifespan.

 

These features make the OWP-BL43-200 Fixed Water Pump a robust and reliable choice for glycol circulation systems, particularly in environments requiring precise control and protection mechanisms.

 

PARAMETER

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 1

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 2

Performance curve

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 3

Technical description (related parts in contact with the liquid)

 

Pump head housing: Aluminum alloy

 

Impeller: PPS+GF

 

Shield cavity: PPS+GF

 

Shaft sleeve: carborundum composite materials

 

Shaft: stainless steel(3CR14) shaft

 

Magnet housing: PPS plastic capsulation

 

Seal ring: EPDM

 

Driving device (Including motor)

 

Driving rotor: PPS plastic capsulated magnet

 

Screws and nuts: SUS 304 stainless steel

 

Driving Motor : brushless motor

 

Motor wire frame :PPA GF

 

Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..

 

Bracket: Steel base

 

Bracket hoop: US 304 stainless steel

 

Waterproof based on IP68 rating (en60529)

 

Connector model: AMP282104-1 (matched Plug AMP282080-1)

 

Nozzle diameter:38mm (1.5 inch)

 

 

DIMENSIONAL DRAWING

 

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 4

APPLICATION GUIDELINES

OWP-BL43-200 series pumps are centrifugal pumps which require pre-filled, The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on.

 

1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.

 

2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.

 

3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).

 

4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .

 

5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )

 

6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).

 

7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium.

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 5

products
PRODUCTS DETAILS
OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System
MOQ: 1 set
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-200
Type:
Single Stage Centrifugal Pump
Operating Voltage:
18-32VDC
Performance:
Q=2400L/H @ H=17M
Waterproofing Grade:
IP68
Noise:
≤61dB
Weight:
2200g
Minimum Order Quantity:
1 set
Price:
Negotiable
Packaging Details:
PE bag+carton
Delivery Time:
5-10days
Payment Terms:
L/C, T/T
Supply Ability:
10000pcs/month
Product Description

OWP-BL43-200 FIXED WATER PUMP 24VDC 250W HIGH HEAD 16M FOR GLYCOL CIRCULATION.

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 0

Features

 

Centrifugal Pump: Utilizes centrifugal force to move fluid, providing consistent and reliable performance.

 

Magnetic Force Transmission: Ensures smooth operation with minimal mechanical wear by using magnetic coupling.

 

High Efficiency Brushless DC Motor:

Low power consumption.

High efficiency.

Long service life.

 

Wide Range Operating Temperature: Capable of functioning effectively across a broad spectrum of temperatures.

 

Constant Flow Controlling: Maintains a steady flow rate, ensuring consistent performance.

 

Reverse Polarity Protection: Prevents damage from incorrect wiring connections.

 

Dry Running Protection: Automatically shuts down if the pump runs without sufficient liquid, protecting the motor from overheating.

 

Over Voltage Protection: Safeguards against electrical surges.

 

Over Current Protection: Protects the pump from excessive current draw.

 

Overload and Over Temperature Protection: Ensures the pump does not exceed safe operational limits, extending its lifespan.

 

These features make the OWP-BL43-200 Fixed Water Pump a robust and reliable choice for glycol circulation systems, particularly in environments requiring precise control and protection mechanisms.

 

PARAMETER

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 1

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 2

Performance curve

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 3

Technical description (related parts in contact with the liquid)

 

Pump head housing: Aluminum alloy

 

Impeller: PPS+GF

 

Shield cavity: PPS+GF

 

Shaft sleeve: carborundum composite materials

 

Shaft: stainless steel(3CR14) shaft

 

Magnet housing: PPS plastic capsulation

 

Seal ring: EPDM

 

Driving device (Including motor)

 

Driving rotor: PPS plastic capsulated magnet

 

Screws and nuts: SUS 304 stainless steel

 

Driving Motor : brushless motor

 

Motor wire frame :PPA GF

 

Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..

 

Bracket: Steel base

 

Bracket hoop: US 304 stainless steel

 

Waterproof based on IP68 rating (en60529)

 

Connector model: AMP282104-1 (matched Plug AMP282080-1)

 

Nozzle diameter:38mm (1.5 inch)

 

 

DIMENSIONAL DRAWING

 

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 4

APPLICATION GUIDELINES

OWP-BL43-200 series pumps are centrifugal pumps which require pre-filled, The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on.

 

1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.

 

2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.

 

3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).

 

4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .

 

5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )

 

6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).

 

7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium.

OWP Series Coolant Pump Specialized For Glycol Circulation and Data Centure and Energy Storage System 5

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2024 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.