Send Message
Home ProductsBLDC Water Pump

Brushless direct current coolant pump for energy stored and EV thermal management.

Certification
China Changzhou Bextreme Shell Motor Technology Co.,Ltd certification
China Changzhou Bextreme Shell Motor Technology Co.,Ltd certification
Customer Reviews
Thank you provided very nice components and professional advices for our project ,and wish you good.

—— Adolph

The motor drivers we got from you worked well and your customized service was very helpful to us.

—— Primo

Your products have a good quality and they are working stably.

—— ED

I'm Online Chat Now

Brushless direct current coolant pump for energy stored and EV thermal management.

Brushless direct current coolant pump for energy stored and EV thermal management.
Brushless direct current coolant pump for energy stored and EV thermal management. Brushless direct current coolant pump for energy stored and EV thermal management. Brushless direct current coolant pump for energy stored and EV thermal management. Brushless direct current coolant pump for energy stored and EV thermal management. Brushless direct current coolant pump for energy stored and EV thermal management.

Large Image :  Brushless direct current coolant pump for energy stored and EV thermal management.

Product Details:
Place of Origin: China
Brand Name: Bextreme shell
Model Number: OWP-BL43-200
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: PE bag+carton
Delivery Time: 5-10days
Payment Terms: L/C, T/T
Supply Ability: 1000PCS/Month

Brushless direct current coolant pump for energy stored and EV thermal management.

Description
Voltage: 12-36VDC Power: 250W
Flow: 2400L/H Head: 16M
High Light:

OWDT 3610M dogs trikes

,

OWDT 3610M Tricycle Powered Dog Trike

,

OWDT 3610M Tricycle Dog Powered Trike

OWP-BL43-200 FIXED WATER PUMP 24VDC 250W HIGH HEAD 16M FOR GLYCOL CIRCULATION.

 Brushless direct current coolant pump for energy stored and EV thermal management. 0

FEATURES

◆Centrifugal pump

◆Magnetic force transmission

◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

◆With wide range operating temperature

◆PWM signal speed controlling(optional)

◆Diagnostic signal output(optional)

◆With constant flow controlling

◆Reverse polarity protection

◆Dry running protection

◆Over Voltage, over current protection

◆Overload, over temperature protection

 

PARAMETER

Brushless direct current coolant pump for energy stored and EV thermal management. 1

Brushless direct current coolant pump for energy stored and EV thermal management. 2

Performance curve

Brushless direct current coolant pump for energy stored and EV thermal management. 3

Technical description (related parts in contact with the liquid)

 

Pump head housing: Aluminum alloy

 

Impeller: PPS+GF

 

Shield cavity: PPS+GF

 

Shaft sleeve: carborundum composite materials

 

Shaft: stainless steel(3CR14) shaft

 

Magnet housing: PPS plastic capsulation

 

Seal ring: EPDM

 

Driving device (Including motor)

 

Driving rotor: PPS plastic capsulated magnet

 

Screws and nuts: SUS 304 stainless steel

 

Driving Motor : brushless motor

 

Motor wire frame :PPA GF

 

Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..

 

Bracket: Steel base

 

Bracket hoop: US 304 stainless steel

 

Waterproof based on IP68 rating (en60529)

 

Connector model: AMP282104-1 (matched Plug AMP282080-1)

 

Nozzle diameter:40mm (1.5 inch)

 

DIMENSIONAL DRAWING

Brushless direct current coolant pump for energy stored and EV thermal management. 4

APPLICATION GUIDELINES

OWP-BL43-200 series pumps are centrifugal pumps which require pre-filled, The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on.

 

1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.

 

2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.

 

3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).

 

4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .

 

5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )

 

6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).

 

7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium.

Brushless direct current coolant pump for energy stored and EV thermal management. 5

Contact Details
Changzhou Bextreme Shell Motor Technology Co.,Ltd

Contact Person: Mr. Amigo Deng

Tel: +86-18994777701

Fax: 86-519-83606689

Send your inquiry directly to us (0 / 3000)