Send Message
products
PRODUCTS DETAILS
Home > Products >
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System

OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System

MOQ: 100 pcs
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-8days
Payment Method: L/C, T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Certification
CE,ROSH
Model Number
OWP-BL43-300
Type:
Single Stage Centrifugal Pump
Voltage::
24VDC
Speed:
Fixed Speed
Power:
250W
Flow Rate:
Q=6000L/H @ H=8m
Highlight:

brushless dc motor with planetary gearbox

,

brushless planetary gear motors

,

6 rpm 12v dc gear motor

Product Description
Pump Major Parameters
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 0
Model No.:OWP-BL43-300
Power Input:24VDC
Rated power:250W
Rated Flow rate :6000L/H @ H=8M
Max Flow:9000L/H
Max Lift Head:11M
---------------------------------------------------------------------------
Medium: glycol(50-60%)+water, dielectric oil,Electronic fluorinated solution
Medium temperature:
Working long hours guaranteed
-40℃ to +85℃ (-40°F to + 185°F)
Nozzle diameter:38mm
Speed Control:Fixed speed
Fault Feedback signal:No
IP Grade:IP68
Service life:>20000hours
Weight:2.2Kg
 
Pump Applications
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 1
EV motor cooling
EV motor controller cooling
Turbocharger intercooler pump
EV battery thermal management
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 2
Battery energy storage cooling
Fuel cell cooling
large-scale GPU cooling
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 3
Industrial cooling system
Immersion cooling
Communication base station cooling
Supercomputer cooling
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 4
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 5
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 6
 
Electricized engineering vehicles IT fluid cooling solutions Battery thermal manage
 
Pump Appearance
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 7
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 8
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 9
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 10
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 11
Our clients come from 36 countires with high reputation in their fields.
 
 
Pump Advantages
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 12
Professional electromagnetic theory design verification ,makes our pump motor 3-5% higher efficiency than other competitors.
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 13
Simulation calculation of hydraulic design by professional software makes our impeller and volute reach to the best match for higher hydraulic efficiency than others
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 14
Automotive grade electronic components makes our pump withstand extreme harsh operating environment
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 15
Software&Tools applied:
CFturbo/ANSYS FLUENT/Compile/Link/Debug/Simulate/Emulate/Program /SlikEdit, TestLink Software guidelines:Code Check;SVN:SW version control system (PVCS);Test plan/tests (white box, black box);Internal audit & release
 
Pump Technical parameter
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 16
Features
Single-stage Centrifugal pump
◆Magnetic force transmission (shield pump structure)
◆High efficiency brushless DC motor, low power consumption, high efficiency, more than 20000hours service life.
◆With wide range operating temperature
◆With constant flow controlling
◆Reverse polarity protection
◆Dry running protection
◆Over Voltage, over current protection
◆Overload, over temperature protection
 
 
Driving device (Including motor)
Driving electromagnet: nylon plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor winding frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and impregnation treatment
Bracket: Steel with powder coating
Bracket hoop: US 304 stainless steel+ Damping rubber ring
Waterproof based on IP68 rating (en60529)
Connector model:AMP282104-1(matched Plug AMP282080-1)
Nozzle diameter:38mm/1.5inch
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 17
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 18
Performance
Temperature parameter
Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
Working ambient temperature: -40℃ to +85℃ (-40°F to +185°F) Humidity ≤90%
Storage temperature: -40℃ to +70℃ (-40°F to +158°F) (up to 100 ℃, but it will shorten the
service life)
■ System pressure
-0.2 to 2.5 bar ( 100℃ (212°F).
The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient temperature.

 
 
Pump overall size
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 19
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 20
 
Manufacturing Technique
 
we have 5 semi-automatic pump production lines in dust-free workshops
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 21
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 22
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 23
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 24
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 25
 
1000m² testing room, UL certified lab and R&D deparment with 175 sets testing machines for pump design and development verification,durability testing,aging testing,performance testing.
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 26
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 27
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 28
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 29
 
Verify capabilities and equipments
Over 50 typical testings performed according to automotive standards
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 30
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 31
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 32
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 33
products
PRODUCTS DETAILS
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System
MOQ: 100 pcs
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-8days
Payment Method: L/C, T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Certification
CE,ROSH
Model Number
OWP-BL43-300
Type:
Single Stage Centrifugal Pump
Voltage::
24VDC
Speed:
Fixed Speed
Power:
250W
Flow Rate:
Q=6000L/H @ H=8m
Minimum Order Quantity:
100 pcs
Price:
Negotiable
Packaging Details:
PE bag+carton
Delivery Time:
5-8days
Payment Terms:
L/C, T/T
Supply Ability:
10000pcs/month
Highlight

brushless dc motor with planetary gearbox

,

brushless planetary gear motors

,

6 rpm 12v dc gear motor

Product Description
Pump Major Parameters
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 0
Model No.:OWP-BL43-300
Power Input:24VDC
Rated power:250W
Rated Flow rate :6000L/H @ H=8M
Max Flow:9000L/H
Max Lift Head:11M
---------------------------------------------------------------------------
Medium: glycol(50-60%)+water, dielectric oil,Electronic fluorinated solution
Medium temperature:
Working long hours guaranteed
-40℃ to +85℃ (-40°F to + 185°F)
Nozzle diameter:38mm
Speed Control:Fixed speed
Fault Feedback signal:No
IP Grade:IP68
Service life:>20000hours
Weight:2.2Kg
 
Pump Applications
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 1
EV motor cooling
EV motor controller cooling
Turbocharger intercooler pump
EV battery thermal management
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 2
Battery energy storage cooling
Fuel cell cooling
large-scale GPU cooling
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 3
Industrial cooling system
Immersion cooling
Communication base station cooling
Supercomputer cooling
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 4
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 5
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 6
 
Electricized engineering vehicles IT fluid cooling solutions Battery thermal manage
 
Pump Appearance
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 7
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 8
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 9
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 10
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 11
Our clients come from 36 countires with high reputation in their fields.
 
 
Pump Advantages
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 12
Professional electromagnetic theory design verification ,makes our pump motor 3-5% higher efficiency than other competitors.
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 13
Simulation calculation of hydraulic design by professional software makes our impeller and volute reach to the best match for higher hydraulic efficiency than others
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 14
Automotive grade electronic components makes our pump withstand extreme harsh operating environment
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 15
Software&Tools applied:
CFturbo/ANSYS FLUENT/Compile/Link/Debug/Simulate/Emulate/Program /SlikEdit, TestLink Software guidelines:Code Check;SVN:SW version control system (PVCS);Test plan/tests (white box, black box);Internal audit & release
 
Pump Technical parameter
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 16
Features
Single-stage Centrifugal pump
◆Magnetic force transmission (shield pump structure)
◆High efficiency brushless DC motor, low power consumption, high efficiency, more than 20000hours service life.
◆With wide range operating temperature
◆With constant flow controlling
◆Reverse polarity protection
◆Dry running protection
◆Over Voltage, over current protection
◆Overload, over temperature protection
 
 
Driving device (Including motor)
Driving electromagnet: nylon plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor winding frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and impregnation treatment
Bracket: Steel with powder coating
Bracket hoop: US 304 stainless steel+ Damping rubber ring
Waterproof based on IP68 rating (en60529)
Connector model:AMP282104-1(matched Plug AMP282080-1)
Nozzle diameter:38mm/1.5inch
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 17
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 18
Performance
Temperature parameter
Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
Working ambient temperature: -40℃ to +85℃ (-40°F to +185°F) Humidity ≤90%
Storage temperature: -40℃ to +70℃ (-40°F to +158°F) (up to 100 ℃, but it will shorten the
service life)
■ System pressure
-0.2 to 2.5 bar ( 100℃ (212°F).
The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient temperature.

 
 
Pump overall size
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 19
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 20
 
Manufacturing Technique
 
we have 5 semi-automatic pump production lines in dust-free workshops
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 21
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 22
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 23
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 24
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 25
 
1000m² testing room, UL certified lab and R&D deparment with 175 sets testing machines for pump design and development verification,durability testing,aging testing,performance testing.
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 26
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 27
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 28
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 29
 
Verify capabilities and equipments
Over 50 typical testings performed according to automotive standards
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 30
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 31
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 32
 
 
OWP Series 24VDC Coolant Pump High Flow Rated 6000L/H at 8m Head Widelu Used in Glycol Circulating and Other Cooling System 33
Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2024 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.