12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles.

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles.

MOQ: 1pcs
Price: Negotiable
Standard Packaging: suite for export
Delivery Period: as confirmed
Payment Method: L/C, T/T, Western Union,paypal
Supply Capacity: 100000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme shell
Certification
CE,
Model Number
OWP-BL93-300/301
Type:
Single Stage Centrifugal Pump
Voltage:
12VDC
Flow&Head:
Q=1800L/H @ H=9m
Power:
100W
Noise:
≤45dB
Weight:
1120g
Waterproofing Grade:
IP68
High Light:

pm Permanent Magnet Stepper Motor

,

permanent stepper motor

,

permanent magnet stepper

Product Description

12V/24VDC input electronic water pump for Battery Management System and intercooler of passenger vehicles. 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 0

Applications

 

Widely used in hybrid bus, hybrid passenger car, electric vehicles, trains, and ships and heating management system of energy storage, liquid cooled charging pile, immersed cooling circulation system of data center and other heating and cooling circulation system.

 

Features

 

◆Centrifugal pump
◆Magnetic force transmission (shield pump structure)
◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.
◆With wide range operating temperature
◆PWM signal speed controlling
◆With constant flow controlling
◆Reverse polarity protection
◆Dry running protection
◆Over Voltage, over current protection
◆Overload, over temperature protection

 

Technical description (related parts in contact with the liquid)


Pump head housing: PPS+GF
Impeller: PPS+GF
Shield cavity: PPS+GF
Shaft sleeve: Carbon resin composite materials
Shaft: stainless steel shaft
Magnet housing: nylon plastic capsulation
Seal ring: EPDM

 

Driving device (Including motor)

 

Driving electromagnet: nylon plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and impregnation treatment
Bracket: Steel with powder coating
Bracket hoop: US 304 stainless steel+ Damping rubber ring
Waterproof based on IP68 rating (en60529)
Connector model: AMP282106-1(matched Plug AMP282088-1)
Nozzle diameter:22.4mm (inner diameter:16mm)

 

Model Specifications

 

OWP-BL93-300-(12VDC)
OWP-BL93-301-(24VDC)

 

Mounting instruction

 

OWP-BL93-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always
immersed in the liquid, or pre-filled the pump before power on .

1: Pump should not be dry-running, even though it can dry-running for 30 seconds (after 30
seconds dry-running, it will automatically stop), Dry running will makes noise, also increasing
abrasion to the shaft and shaft sleeve.
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter
hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the
pump through the pipeline, it will make the pump performance degradation, and also the air
bubbles make damage to the pump.
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on
the outlet port).
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed
vertically, the outlet port should be upward .
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should
be vertical or in the upper of the impeller. (see figure 1 )
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air
discharged easily, the outlet pipe should not be used less than 90 degrees
Elbow (see figure 2).
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid
medium .

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 1

                 Figure 1                            Figure 2

 

 

Temperature parameter

 

Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
Working ambient temperature: -40℃ to +85℃ (-40°F to +185°F) Humidity ≤90%
Storage temperature: -40℃ to +70℃ (-40°F to +158°F) (up to 100 ℃, but it will shorten the
service life)

 

System pressure

-0.2 to 2.5 bar ( 100℃ (212°F).
The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient
temperature.

 

Voltage range

 

Rated 12V water pump, workable range 9V - 16V
Rated 24V water pump, workable range 18V - 30V
Although the motor can be used in a wide range of voltage and temperature, but excessive or too
low voltage and temperature will affect the service life of the motor, the pump can not be
exposed to thermal radiation ambient.

 

Medium liquid: pure water, liquid mixture (Water with below 60% glycol)

 

Electrical parameter

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 2

 

PWM character

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 3

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 4

Attentions

 

1. Working ambient temperature:-40℃--85℃, should try to avoid close to three-element
catalytic, gas discharge pipe system and engine during the installation, ensure the working
environment temperature.
2.The installation position of the water pump should as much as possible close to the low water
level , to extend the service life of the pump.
3. Please use the pump far from the dusty environment, the dust is harmful to reduce the service
life
4. Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the
service life of pump

 

Performance parameter

 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 5

External dimensions

 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 6

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 7

products
PRODUCTS DETAILS
12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles.
MOQ: 1pcs
Price: Negotiable
Standard Packaging: suite for export
Delivery Period: as confirmed
Payment Method: L/C, T/T, Western Union,paypal
Supply Capacity: 100000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme shell
Certification
CE,
Model Number
OWP-BL93-300/301
Type:
Single Stage Centrifugal Pump
Voltage:
12VDC
Flow&Head:
Q=1800L/H @ H=9m
Power:
100W
Noise:
≤45dB
Weight:
1120g
Waterproofing Grade:
IP68
Minimum Order Quantity:
1pcs
Price:
Negotiable
Packaging Details:
suite for export
Delivery Time:
as confirmed
Payment Terms:
L/C, T/T, Western Union,paypal
Supply Ability:
100000pcs/month
High Light

pm Permanent Magnet Stepper Motor

,

permanent stepper motor

,

permanent magnet stepper

Product Description

12V/24VDC input electronic water pump for Battery Management System and intercooler of passenger vehicles. 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 0

Applications

 

Widely used in hybrid bus, hybrid passenger car, electric vehicles, trains, and ships and heating management system of energy storage, liquid cooled charging pile, immersed cooling circulation system of data center and other heating and cooling circulation system.

 

Features

 

◆Centrifugal pump
◆Magnetic force transmission (shield pump structure)
◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.
◆With wide range operating temperature
◆PWM signal speed controlling
◆With constant flow controlling
◆Reverse polarity protection
◆Dry running protection
◆Over Voltage, over current protection
◆Overload, over temperature protection

 

Technical description (related parts in contact with the liquid)


Pump head housing: PPS+GF
Impeller: PPS+GF
Shield cavity: PPS+GF
Shaft sleeve: Carbon resin composite materials
Shaft: stainless steel shaft
Magnet housing: nylon plastic capsulation
Seal ring: EPDM

 

Driving device (Including motor)

 

Driving electromagnet: nylon plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and impregnation treatment
Bracket: Steel with powder coating
Bracket hoop: US 304 stainless steel+ Damping rubber ring
Waterproof based on IP68 rating (en60529)
Connector model: AMP282106-1(matched Plug AMP282088-1)
Nozzle diameter:22.4mm (inner diameter:16mm)

 

Model Specifications

 

OWP-BL93-300-(12VDC)
OWP-BL93-301-(24VDC)

 

Mounting instruction

 

OWP-BL93-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always
immersed in the liquid, or pre-filled the pump before power on .

1: Pump should not be dry-running, even though it can dry-running for 30 seconds (after 30
seconds dry-running, it will automatically stop), Dry running will makes noise, also increasing
abrasion to the shaft and shaft sleeve.
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter
hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the
pump through the pipeline, it will make the pump performance degradation, and also the air
bubbles make damage to the pump.
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on
the outlet port).
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed
vertically, the outlet port should be upward .
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should
be vertical or in the upper of the impeller. (see figure 1 )
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air
discharged easily, the outlet pipe should not be used less than 90 degrees
Elbow (see figure 2).
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid
medium .

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 1

                 Figure 1                            Figure 2

 

 

Temperature parameter

 

Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
Working ambient temperature: -40℃ to +85℃ (-40°F to +185°F) Humidity ≤90%
Storage temperature: -40℃ to +70℃ (-40°F to +158°F) (up to 100 ℃, but it will shorten the
service life)

 

System pressure

-0.2 to 2.5 bar ( 100℃ (212°F).
The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient
temperature.

 

Voltage range

 

Rated 12V water pump, workable range 9V - 16V
Rated 24V water pump, workable range 18V - 30V
Although the motor can be used in a wide range of voltage and temperature, but excessive or too
low voltage and temperature will affect the service life of the motor, the pump can not be
exposed to thermal radiation ambient.

 

Medium liquid: pure water, liquid mixture (Water with below 60% glycol)

 

Electrical parameter

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 2

 

PWM character

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 3

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 4

Attentions

 

1. Working ambient temperature:-40℃--85℃, should try to avoid close to three-element
catalytic, gas discharge pipe system and engine during the installation, ensure the working
environment temperature.
2.The installation position of the water pump should as much as possible close to the low water
level , to extend the service life of the pump.
3. Please use the pump far from the dusty environment, the dust is harmful to reduce the service
life
4. Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the
service life of pump

 

Performance parameter

 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 5

External dimensions

 

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 6

12V DC input electronic coolant pump driven by brushless motor for inter coolers and BTMS of vehicles. 7

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2024 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.