Send Message
products
PRODUCTS DETAILS
Home > Products >
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation

MOQ: 5 sets
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000 sets per month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-300
Usage:
Flood System, Viscous Media And Liquid
Voltage:
18-32V
Power:
130W\200W\250W
Theory:
Centrifugal Pump
Product Name:
Brushless DC Pump For Liquid Cooled Glycol Circulation
Material:
Cast Aluminium/Stainless Steel
Waterproof:
IP68
Color:
Silver
Highlight:

High Flow BLDC Water Pump

,

250W BLDC Water Pump

,

6000L/H bldc pump

Product Description

Bextreme Shell 18V-32V 250W Brushless DC Water Pump 6000L/H Low-Noise For Liquid Cooled Glycol Circulation Flood system Viscous Media and Liquid.

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 0

 

 

OWP-BL43-300 SERIES brushless DC water pump

Boosting/circulation/Variable-frequency/Low-noise/centrifugal pump

 

The OWP-BL43-300 automotive water pump, an advanced and efficient solution for various water pumping needs. This pump boasts a range of impressive features to ensure optimal performance and durability. Its centrifugal pump design, coupled with the magnetic force transmission system, guarantees efficient water circulation. Equipped with a high-efficiency brushless DC motor, this pump consumes minimal power while delivering outstanding performance. With its dry running protection and a wide operating temperature range, it offers reliable operation even in challenging conditions. The pump also incorporates multiple safety measures, such as reverse polarity protection, overvoltage and overcurrent protection, as well as overload and over-temperature protection. Experience the benefits of this water pump's energy efficiency, long service life, and constant flow control, making it an ideal choice for automotive applications.

■Performance parameter

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 1

 

Electrical parameter

 

Working Voltage

(VDC)

Rated power

Rated flow

(L/H)

Dimensions

(mm)

Weight

(g)

 

 

 

18V-32V(24V)

 

130W

Q=5000L/H,

H≥5m

 

 

 

195*90*145

 

 

 

1950g

 

200W

Q=6000L/H,

H≥6m

 

250W

Q=6000L/H,

H≥8m

 
Connector model and the corresponding electrical properties (as shown below):
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 2

AMP282104-1

(matched Plug AMP282080-1)

1 2
+24V DC GND

 

■Selling point

  • Centrifugal pump

  • Magnetic force transmission

  • High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

  • With wide range operating temperature

  • PWM signal speed controlling(optional)

  • Diagnostic signal output(optional)

  • With constant flow controlling

  • Reverse polarity protection

  • Dry running protection

  • Over Voltage, over current protection

  • Overload, over temperature protection

 

Driving device (Including motor)

 
Driving rotor: PPS plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..
 
Bracket: Steel base
Bracket hoop: US 304 stainless steel
Waterproof based on IP68 rating (en60529)
Connector model: AMP282104-1 (matched Plug AMP282080-1)
Nozzle diameter:40mm (1.5 inch)
 

■Technical description (related parts in contact with the liquid)

Pump head housing: Aluminum alloy
Impeller: PPS+GF Shield cavity: PPS+GF
Shaft sleeve: carborundum composite materials
Shaft: stainless steel(3CR14) shaft
Magnet housing: PPS plastic capsulation
Seal ring: EPDM
 

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 3■ Mounting instruction

 
OWP-BL43-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .
 
1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.
 
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.
 
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).
 
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .
 
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )
 
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).
 
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 4

 

■External dimension

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 5

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 6

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 3■ Attentions

 
1.Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and       engine during the installation, ensure the working environment temperature.
2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the   pump.
 
3.Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
4.Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
 
 

 

■ Applicatons

Cooling system of the server

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 8

Cooling system of HEV  bus BHEV

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 9

 



 

products
PRODUCTS DETAILS
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation
MOQ: 5 sets
Price: Negotiable
Standard Packaging: PE bag+carton
Delivery Period: 5-10days
Payment Method: L/C, T/T
Supply Capacity: 10000 sets per month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL43-300
Usage:
Flood System, Viscous Media And Liquid
Voltage:
18-32V
Power:
130W\200W\250W
Theory:
Centrifugal Pump
Product Name:
Brushless DC Pump For Liquid Cooled Glycol Circulation
Material:
Cast Aluminium/Stainless Steel
Waterproof:
IP68
Color:
Silver
Minimum Order Quantity:
5 sets
Price:
Negotiable
Packaging Details:
PE bag+carton
Delivery Time:
5-10days
Payment Terms:
L/C, T/T
Supply Ability:
10000 sets per month
Highlight

High Flow BLDC Water Pump

,

250W BLDC Water Pump

,

6000L/H bldc pump

Product Description

Bextreme Shell 18V-32V 250W Brushless DC Water Pump 6000L/H Low-Noise For Liquid Cooled Glycol Circulation Flood system Viscous Media and Liquid.

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 0

 

 

OWP-BL43-300 SERIES brushless DC water pump

Boosting/circulation/Variable-frequency/Low-noise/centrifugal pump

 

The OWP-BL43-300 automotive water pump, an advanced and efficient solution for various water pumping needs. This pump boasts a range of impressive features to ensure optimal performance and durability. Its centrifugal pump design, coupled with the magnetic force transmission system, guarantees efficient water circulation. Equipped with a high-efficiency brushless DC motor, this pump consumes minimal power while delivering outstanding performance. With its dry running protection and a wide operating temperature range, it offers reliable operation even in challenging conditions. The pump also incorporates multiple safety measures, such as reverse polarity protection, overvoltage and overcurrent protection, as well as overload and over-temperature protection. Experience the benefits of this water pump's energy efficiency, long service life, and constant flow control, making it an ideal choice for automotive applications.

■Performance parameter

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 1

 

Electrical parameter

 

Working Voltage

(VDC)

Rated power

Rated flow

(L/H)

Dimensions

(mm)

Weight

(g)

 

 

 

18V-32V(24V)

 

130W

Q=5000L/H,

H≥5m

 

 

 

195*90*145

 

 

 

1950g

 

200W

Q=6000L/H,

H≥6m

 

250W

Q=6000L/H,

H≥8m

 
Connector model and the corresponding electrical properties (as shown below):
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 2

AMP282104-1

(matched Plug AMP282080-1)

1 2
+24V DC GND

 

■Selling point

  • Centrifugal pump

  • Magnetic force transmission

  • High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

  • With wide range operating temperature

  • PWM signal speed controlling(optional)

  • Diagnostic signal output(optional)

  • With constant flow controlling

  • Reverse polarity protection

  • Dry running protection

  • Over Voltage, over current protection

  • Overload, over temperature protection

 

Driving device (Including motor)

 
Driving rotor: PPS plastic capsulated magnet
Screws and nuts: SUS 304 stainless steel
Driving Motor : brushless motor
Motor wire frame :PPA GF
Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..
 
Bracket: Steel base
Bracket hoop: US 304 stainless steel
Waterproof based on IP68 rating (en60529)
Connector model: AMP282104-1 (matched Plug AMP282080-1)
Nozzle diameter:40mm (1.5 inch)
 

■Technical description (related parts in contact with the liquid)

Pump head housing: Aluminum alloy
Impeller: PPS+GF Shield cavity: PPS+GF
Shaft sleeve: carborundum composite materials
Shaft: stainless steel(3CR14) shaft
Magnet housing: PPS plastic capsulation
Seal ring: EPDM
 

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 3■ Mounting instruction

 
OWP-BL43-300 series pumps are centrifugal pumps which require pre-filled,
The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .
 
1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.
 
2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.
 
3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).
 
4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .
 
5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )
 
6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).
 
7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .
High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 4

 

■External dimension

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 5

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 6

 

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 3■ Attentions

 
1.Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and       engine during the installation, ensure the working environment temperature.
2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the   pump.
 
3.Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
4.Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
 
 

 

■ Applicatons

Cooling system of the server

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 8

Cooling system of HEV  bus BHEV

High Flow BLDC Water Pump 250W 6000L/H For Liquid Cooled Glycol Circulation 9

 



 

Sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2025 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.