logo
Products
PRODUCTS DETAILS
Home > Products >
OWP-BL1500H-D3-1 — 150 L/min at 30 m Head for In-Row CDU Circulation Duty

OWP-BL1500H-D3-1 — 150 L/min at 30 m Head for In-Row CDU Circulation Duty

MOQ: 1
Price: Negotiable
Standard Packaging: Cartons
Delivery Period: 20 work days
Payment Method: T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL1500H-D3-1
Rated Voltage:
DC48V
Highlight:

electric coolant pump 150 L/min

,

in-row CDU circulation pump

,

30 m head coolant pump

Product Description

OWP-BL1500H-D3-1 — 150 L/min at 30 m Head for In-Row CDU Circulation Duty

Product Overview

Positioned between facility water and IT loops, an in-row CDU needs a circulation pump that sustains high flow against real-world pressure loss. The OWP-BL1500H-D3-1 answers this with 150 L/min at 30 m head on a DC48V supply, in a seal-less canned centrifugal configuration. It handles deionized water or glycol mixtures, tolerates -0.75 to 10 Bar system pressure, and reports status over RS485 for continuous supervision.

Specifications

Category Parameter Value
Power supply Rated / operating voltage DC48V / DC36–58V
Rated power 1500W
Hydraulic performance Flow–head point 150 L/min @ 30 m
Pressure envelope -0.75 ~ 10 Bar
Noise emission At 1 m distance ≤65 dB
Operating conditions Temperature (air & fluid) -40°C ~ 65°C
Humidity / altitude 5–95% / ≤3000 m
Wetted materials Metal parts 304 stainless steel
Fittings Port bore / clamp φ30 mm / φ64 mm tri-clamp
Reliability Design life ≥20,000 h
Control & protection Interface / ingress rating RS485 / IP67

Application

In-row CDUs serve one or more racks from a floor-standing position, so their internal pumps face the combined resistance of heat exchangers, manifolds, and hose runs. The 30 m head covers such multi-component loops, while the -0.75 Bar lower bound accommodates transient suction conditions during filling or low-tank operation. Tri-clamp φ64 mm connections simplify swapping during scheduled service, keeping row-level uptime high.

Main Points & Industry Demands

Row-level cooling concentrates flow for several racks, which raises both hydraulic resistance and the cost of downtime. Operators expect the CDU pump to run unattended for years, track its condition remotely, and avoid any coolant release near powered equipment. Energy use also matters at row scale: a pump that adds less heat and draws less power reduces the facility overhead assigned to cooling. The result is a requirement profile centered on durable hydraulics, seal-less integrity, and communication-driven visibility rather than raw size.

Product Advantages as Core Solutions

  • 30 m head @ 150 L/min → surplus pressure for exchangers and long pipe runs → stable row-level delivery even as filters load up over time.
  • Canned, seal-less rotor chamber → no mechanical seal to fail → eliminates coolant leakage at the pump, protecting adjacent rack power distribution.
  • RS485 interface → speed and status feedback → enables predictive maintenance scheduling instead of reactive repair.
  • 20,000 h-plus bearing system → extended overhaul intervals → lower row total cost of ownership across multi-year deployment.

Operational Mechanism

The permanent-magnet synchronous motor rotates the impeller inside a sealed stainless steel chamber. Entering fluid is captured by the twisted impeller blades and flung outward, building pressure in the volute; the can wall isolates the rotor electrically while allowing full fluid contact for cooling and lubrication. Because there is no shaft seal, friction losses and leak paths are structurally removed.

Selection Guide

At the industry reference ratio of 1.5 L/min per kW, this unit's rated flow supports approximately 100 kW of dissipated heat—enough for a typical in-row CDU serving several standard racks, and adequate for many high-density rows with N+1 redundancy. Glycol loops and fine-pore filters add resistance, so verify that the operating point remains on the pump curve at the project's actual fluid mix and temperature.

FAQ

Q1: How is after-sales coverage arranged for fleet deployments?

A: The product is covered by a two-year warranty, and rapid-response technical support is provided.

Q2: What is the realistic in-service lifespan?

A: Working life exceeds 20,000 hours under rated conditions.

Q3: Can you handle volume orders for multi-row rollouts?

A: Yes—lead time is 20 working days at a monthly capacity of 10,000 units.

Products
PRODUCTS DETAILS
OWP-BL1500H-D3-1 — 150 L/min at 30 m Head for In-Row CDU Circulation Duty
MOQ: 1
Price: Negotiable
Standard Packaging: Cartons
Delivery Period: 20 work days
Payment Method: T/T
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL1500H-D3-1
Rated Voltage:
DC48V
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Cartons
Delivery Time:
20 work days
Payment Terms:
T/T
Supply Ability:
10000pcs/month
Highlight

electric coolant pump 150 L/min

,

in-row CDU circulation pump

,

30 m head coolant pump

Product Description

OWP-BL1500H-D3-1 — 150 L/min at 30 m Head for In-Row CDU Circulation Duty

Product Overview

Positioned between facility water and IT loops, an in-row CDU needs a circulation pump that sustains high flow against real-world pressure loss. The OWP-BL1500H-D3-1 answers this with 150 L/min at 30 m head on a DC48V supply, in a seal-less canned centrifugal configuration. It handles deionized water or glycol mixtures, tolerates -0.75 to 10 Bar system pressure, and reports status over RS485 for continuous supervision.

Specifications

Category Parameter Value
Power supply Rated / operating voltage DC48V / DC36–58V
Rated power 1500W
Hydraulic performance Flow–head point 150 L/min @ 30 m
Pressure envelope -0.75 ~ 10 Bar
Noise emission At 1 m distance ≤65 dB
Operating conditions Temperature (air & fluid) -40°C ~ 65°C
Humidity / altitude 5–95% / ≤3000 m
Wetted materials Metal parts 304 stainless steel
Fittings Port bore / clamp φ30 mm / φ64 mm tri-clamp
Reliability Design life ≥20,000 h
Control & protection Interface / ingress rating RS485 / IP67

Application

In-row CDUs serve one or more racks from a floor-standing position, so their internal pumps face the combined resistance of heat exchangers, manifolds, and hose runs. The 30 m head covers such multi-component loops, while the -0.75 Bar lower bound accommodates transient suction conditions during filling or low-tank operation. Tri-clamp φ64 mm connections simplify swapping during scheduled service, keeping row-level uptime high.

Main Points & Industry Demands

Row-level cooling concentrates flow for several racks, which raises both hydraulic resistance and the cost of downtime. Operators expect the CDU pump to run unattended for years, track its condition remotely, and avoid any coolant release near powered equipment. Energy use also matters at row scale: a pump that adds less heat and draws less power reduces the facility overhead assigned to cooling. The result is a requirement profile centered on durable hydraulics, seal-less integrity, and communication-driven visibility rather than raw size.

Product Advantages as Core Solutions

  • 30 m head @ 150 L/min → surplus pressure for exchangers and long pipe runs → stable row-level delivery even as filters load up over time.
  • Canned, seal-less rotor chamber → no mechanical seal to fail → eliminates coolant leakage at the pump, protecting adjacent rack power distribution.
  • RS485 interface → speed and status feedback → enables predictive maintenance scheduling instead of reactive repair.
  • 20,000 h-plus bearing system → extended overhaul intervals → lower row total cost of ownership across multi-year deployment.

Operational Mechanism

The permanent-magnet synchronous motor rotates the impeller inside a sealed stainless steel chamber. Entering fluid is captured by the twisted impeller blades and flung outward, building pressure in the volute; the can wall isolates the rotor electrically while allowing full fluid contact for cooling and lubrication. Because there is no shaft seal, friction losses and leak paths are structurally removed.

Selection Guide

At the industry reference ratio of 1.5 L/min per kW, this unit's rated flow supports approximately 100 kW of dissipated heat—enough for a typical in-row CDU serving several standard racks, and adequate for many high-density rows with N+1 redundancy. Glycol loops and fine-pore filters add resistance, so verify that the operating point remains on the pump curve at the project's actual fluid mix and temperature.

FAQ

Q1: How is after-sales coverage arranged for fleet deployments?

A: The product is covered by a two-year warranty, and rapid-response technical support is provided.

Q2: What is the realistic in-service lifespan?

A: Working life exceeds 20,000 hours under rated conditions.

Q3: Can you handle volume orders for multi-row rollouts?

A: Yes—lead time is 20 working days at a monthly capacity of 10,000 units.

sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2026 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.