logo
Products
PRODUCTS DETAILS
Home > Products >
OWP-BL1500H-D3-1 — DC48V Seal-less Circulation Pump for ICT Server Cooling Loops

OWP-BL1500H-D3-1 — DC48V Seal-less Circulation Pump for ICT Server Cooling Loops

MOQ: 1
Price: Negotiable
Standard Packaging: Cartons
Delivery Period: 20 work days
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL1500H-D3-1
Product Name:
Coolant Pump
Medium:
Antifreeze
Rated Voltage:
DC48V (36–58V)
Material:
SUS 304
Performance:
Q=200L/min @H=27m
Pump Type:
Single-stage Centrifugal
Pump Structure:
Canned Pump
Power:
1500W
Flow Rate:
150 L/min
Max Head:
30 M
System Pressure:
-0.75 To 10 Bar
Noise Level:
≤65 DB @ 1 M
Operating Temperature:
-40°C~65°C
Wetted Material:
304 Stainless Steel
Ingress Protection:
IP67
Rated Life:
≥20,000 H
Highlight:

DC48V seal-less circulation pump

,

ICT server cooling loop pump

,

BLDC driver board circulation pump

Product Description

OWP-BL1500H-D3-1 — DC48V Seal-less Circulation Pump for ICT Server Cooling Loops

Product Overview

Server-grade direct liquid cooling depends on a pump that preserves coolant purity and runs quietly for years. The OWP-BL1500H-D3-1 circulates deionized water or antifreeze at 150 L/min and 30 m head from a DC48V bus, in a fully sealed centrifugal configuration with IP67 ingress protection. Wetted surfaces are 304 stainless steel, and RS485 provides the monitoring channel expected in ICT infrastructure.

Specifications

Class Item Rating
Electrical input Voltage DC48V (36–58V)
Power 1500W
Hydraulic duty point Flow / head 150 L/min / 30 m
System pressure -0.75 to 10 Bar
Sound Noise level ≤65 dB @ 1 m
Media & environment Fluids / temperature Deionized water, antifreeze / -40°C~65°C
Humidity / altitude 5–95% / ≤3000 m
Wetted construction Metal components 304 stainless steel
Ports Bore / clamp size φ30 mm / φ64 mm quick clamp
Durability Rated life ≥20,000 h
Integration Protocol / protection RS485 / IP67

Application

In ICT server cooling, the pump sits between the CDU and cold-plate manifolds. Deionized water demands contamination-free wetted paths—hence stainless steel construction and a seal-less rotor. The 10 Bar ceiling covers pressurized manifold designs, and the wide DC input range matches battery-buffered 48V distribution common in telecom-grade power systems. Low noise suits white-space corridors where technicians work continuously.

Main Points & Industry Demands

Server cooling loops operate on small temperature differences, so sustained flow—not peak pressure—carries the thermal load. Any interruption or contamination event risks thermal shutdown of IT assets, which makes reliability and media cleanliness the governing criteria. Facilities also standardize on 48V DC infrastructure and expect every device to report status digitally. A server-cooling pump must therefore combine stainless fluid paths, seal-less integrity, DC bus compatibility, and a real-time communication interface within a compact, low-noise envelope.

Product Advantages as Core Solutions

304 stainless wetted parts → corrosion resistance and cleanliness → maintains deionized water resistivity over the service period.
Canned design → absence of dynamic seals → no particle generation or weepage into precision cold plates and microchannels.
DC36–58V window → direct connection to ICT 48V plants → simplifies power architecture without intermediate conversion stages.
Closed twisted impeller → efficient conversion of 1500W into flow → adequate head for cold-plate strings with margin for filter fouling.

Operational Mechanism

Coolant is drawn axially into a shrouded impeller; the twisted blades impart angular velocity, and the surrounding volute decelerates the stream to raise static pressure. The motor's rotor runs inside a thin stainless can immersed in the pumped fluid, which both cools the winding-adjacent region and lubricates the ultra-long-life friction pair. Electronics commutate the motor and expose speed and diagnostics on RS485.

Selection Guide

Following the 1.5 L/min-per-kW convention, 150 L/min corresponds to about 100 kW—sufficient for a full server-cooling distribution loop serving dozens of nodes, depending on manifold design. Since server loops usually run with generous design margin, confirm actual head loss across cold plates and quick disconnects; undersized return paths can shift the operating point and erode the apparent margin.

FAQ

Q1: Can the pump interface with our DCIM monitoring platform?

A: It communicates via RS485, and rapid-response technical support assists with integration.

Q2: Is dimensional or hydraulic customization available?

A: Customization is supported for project-specific requirements.

Q3: What warranty terms apply to ICT deployments?

A: Two-year warranty, with a working life exceeding 20,000 hours.

Products
PRODUCTS DETAILS
OWP-BL1500H-D3-1 — DC48V Seal-less Circulation Pump for ICT Server Cooling Loops
MOQ: 1
Price: Negotiable
Standard Packaging: Cartons
Delivery Period: 20 work days
Supply Capacity: 10000pcs/month
Detail Information
Place of Origin
China
Brand Name
Bextreme Shell
Model Number
OWP-BL1500H-D3-1
Product Name:
Coolant Pump
Medium:
Antifreeze
Rated Voltage:
DC48V (36–58V)
Material:
SUS 304
Performance:
Q=200L/min @H=27m
Pump Type:
Single-stage Centrifugal
Pump Structure:
Canned Pump
Power:
1500W
Flow Rate:
150 L/min
Max Head:
30 M
System Pressure:
-0.75 To 10 Bar
Noise Level:
≤65 DB @ 1 M
Operating Temperature:
-40°C~65°C
Wetted Material:
304 Stainless Steel
Ingress Protection:
IP67
Rated Life:
≥20,000 H
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
Cartons
Delivery Time:
20 work days
Supply Ability:
10000pcs/month
Highlight

DC48V seal-less circulation pump

,

ICT server cooling loop pump

,

BLDC driver board circulation pump

Product Description

OWP-BL1500H-D3-1 — DC48V Seal-less Circulation Pump for ICT Server Cooling Loops

Product Overview

Server-grade direct liquid cooling depends on a pump that preserves coolant purity and runs quietly for years. The OWP-BL1500H-D3-1 circulates deionized water or antifreeze at 150 L/min and 30 m head from a DC48V bus, in a fully sealed centrifugal configuration with IP67 ingress protection. Wetted surfaces are 304 stainless steel, and RS485 provides the monitoring channel expected in ICT infrastructure.

Specifications

Class Item Rating
Electrical input Voltage DC48V (36–58V)
Power 1500W
Hydraulic duty point Flow / head 150 L/min / 30 m
System pressure -0.75 to 10 Bar
Sound Noise level ≤65 dB @ 1 m
Media & environment Fluids / temperature Deionized water, antifreeze / -40°C~65°C
Humidity / altitude 5–95% / ≤3000 m
Wetted construction Metal components 304 stainless steel
Ports Bore / clamp size φ30 mm / φ64 mm quick clamp
Durability Rated life ≥20,000 h
Integration Protocol / protection RS485 / IP67

Application

In ICT server cooling, the pump sits between the CDU and cold-plate manifolds. Deionized water demands contamination-free wetted paths—hence stainless steel construction and a seal-less rotor. The 10 Bar ceiling covers pressurized manifold designs, and the wide DC input range matches battery-buffered 48V distribution common in telecom-grade power systems. Low noise suits white-space corridors where technicians work continuously.

Main Points & Industry Demands

Server cooling loops operate on small temperature differences, so sustained flow—not peak pressure—carries the thermal load. Any interruption or contamination event risks thermal shutdown of IT assets, which makes reliability and media cleanliness the governing criteria. Facilities also standardize on 48V DC infrastructure and expect every device to report status digitally. A server-cooling pump must therefore combine stainless fluid paths, seal-less integrity, DC bus compatibility, and a real-time communication interface within a compact, low-noise envelope.

Product Advantages as Core Solutions

304 stainless wetted parts → corrosion resistance and cleanliness → maintains deionized water resistivity over the service period.
Canned design → absence of dynamic seals → no particle generation or weepage into precision cold plates and microchannels.
DC36–58V window → direct connection to ICT 48V plants → simplifies power architecture without intermediate conversion stages.
Closed twisted impeller → efficient conversion of 1500W into flow → adequate head for cold-plate strings with margin for filter fouling.

Operational Mechanism

Coolant is drawn axially into a shrouded impeller; the twisted blades impart angular velocity, and the surrounding volute decelerates the stream to raise static pressure. The motor's rotor runs inside a thin stainless can immersed in the pumped fluid, which both cools the winding-adjacent region and lubricates the ultra-long-life friction pair. Electronics commutate the motor and expose speed and diagnostics on RS485.

Selection Guide

Following the 1.5 L/min-per-kW convention, 150 L/min corresponds to about 100 kW—sufficient for a full server-cooling distribution loop serving dozens of nodes, depending on manifold design. Since server loops usually run with generous design margin, confirm actual head loss across cold plates and quick disconnects; undersized return paths can shift the operating point and erode the apparent margin.

FAQ

Q1: Can the pump interface with our DCIM monitoring platform?

A: It communicates via RS485, and rapid-response technical support assists with integration.

Q2: Is dimensional or hydraulic customization available?

A: Customization is supported for project-specific requirements.

Q3: What warranty terms apply to ICT deployments?

A: Two-year warranty, with a working life exceeding 20,000 hours.

sitemap |  Privacy Policy | China Good Quality BLDC Driver Board Supplier. Copyright © 2021-2026 Changzhou Bextreme Shell Motor Technology Co.,Ltd . All Rights Reserved.